Unitas Condensationis Evaporativae Typi Tractus Inducti Refrigerator Condensationis Evaporativae
Descriptio Societatis
 
 		     			Descriptio Producti
 
 		     			<
| Exemplar Producti | Commutatio caloris nominalis (kW) | Ventilator Axis | Fluxus m³/h | Potentia (kW) | Pondus transportationis | |||
| Fluxus aeris m³/h | Potentia singularis (kW) | Numerus | ||||||
| ZFS-390 | 390kW | 13 | 4.00 | 1 | 50 | 1.10 | 2050 | 4350 | 
| ZFS-430 | 430 kW | 12 | 4.00 | 1 | 50 | 1.10 | 2190 | 4950 | 
| ZFS-465 | 465 kW | 13 | 4.00 | 1 | 50 | 1.10 | 2270 | 5200 | 
| ZFS-500 | 500 kW | 11 | 4.00 | 1 | 70 | 1.50 | 2450 | 5350 | 
| ZFS-600 | 600 kW | 22 | 5.50 | 1 | 70 | 1.50 | 2700 | 6100 | 
| ZFS-650 | 650 kW | 22 | 5.50 | 1 | 80 | 2.20 | 2860 | 6200 | 
| ZFS-700 | 700 kW | 19 | 5.50 | 1 | 80 | 2.20 | 2870 | 6300 | 
| ZFS-800 | 800 kW | 22 | 7.50 | 1 | centum | 4.00 | 3360 | 7150 | 
| ZFS-700 | 700 kW | 25 | 3.00 | 2 | 70 | 2.00 | 3160 | 7300 | 
| ZFS-800 | 800 kW | 25 | 3.00 | 2 | 70 | 2.00 | 3560 | 8500 | 
| ZFS-900 | 900 kW | 32 | 5.50 | 2 | 90 | 3.00 | 3780 | 9050 | 
| ZFS-1000 | 1000 kW | 31 | 5.50 | 2 | CXX | 4.00 | Quadringenta milia | 9700 | 
| ZFS-1150 | 1150 kW | 35 | 7.50 | 2 | CL | 4.00 | 4485 | 10600 | 
| ZFS-1280 | 1280 kW | 42 | 7.50 | 2 | CL | 4.00 | 4736 | 11560 | 
| ZFS-1490 | 1490 kW | 47 | 7.50 | 2 | CLXXX | 4.00 | 5513 | 13800 | 
| ZFS-1540 | 1540 kW | 45 | 7.50 | 2 | CLXXX | 4.00 | 5698 | 13900 | 
| ZFS-1050 | 1050 kW | 31 | 4.00 | 3 | CL | 4.00 | 4515 | 11200 | 
| ZFS-1260 | 1260 kW | 38 | 5.50 | 3 | CL | 4.00 | 5166 | 11850 | 
| ZFS-1480 | 1480 kW | 52 | 5.50 | 3 | CL | 4.00 | 5950 | 13900 | 
| ZFS-1540 | 1540 kW | 58 | 5.50 | 3 | CLXXX | 4.00 | 6129 | 14850 | 
| ZFS-1750 | 1750 kW | 66 | 5.50 | 3 | CLXXX | 4.00 | 6860 | 16200 | 
| ZFS-2000 | 2000 kW | 75 | 7.50 | 3 | ducenti | 4.00 | 7840 | 17800 | 
| ZFS-2200 | 2200 kW | 78 | 7.50 | 3 | ducenti | 4.00 | 8096 | 19500 | 
| ZFS-3000 | 3000 kW | 94 | 11 | 3 | 320 | 2*4.0 | 10950 | 24750 | 
Commoda
1. Alta efficacia commutationis caloris: Efficax commutator caloris designum translationis caloris singulare adhibet, et efficacia commutationis caloris refluxus inter aerem et aquam in lateribus interioribus et exterioribus spirae efficitur.
2, systema impulsionis fidum: usus motoris plene inclusi, certam capacitatem onerandi habet, et longam vitam servitii.
3, fenestra aeris efficax: fenestra aeris unica trium canalium pulverem in atmosphaera in alveum aquae efficaciter reducere potest.
4, facilis cura: alveus aquarius designo inclinato est, facile purgatur; et facile sordes ex alveo aquario exhaurire potest.
Applicatio
1. Praerefrigeratio fructuum et olerum, conservatio, conservatio atmosphaerae moderatae (conservatio CA) et congelatio-siccatio, etc.
 2. Exclusio avium et carnis, praerefrigeratio, congelatio celeris et repositio congelationis, etc.
 3. Cibus marinus (pisces et squillae, etc.) celeriter congelatus, repositus et repositus congelationis profundae ad -60℃.
 4. Refrigeratio chemica.
 5. Refrigerator aquae ad refrigerationem aeris officinae, ad cibum avium tractandum, et cetera.
 6. Antlia calorica quae aquam calidam ad pennas avium removendas, etc., producit.
Si interest tibi, nobiscum contactum fac, solutionem integram mittemus.
 Elige refrigerationem frigidariam, elige professionem et bonum officium.
 
                 